Page 14 - \\tsclient\C\Users\Jack Weeks\Desktop\TS Injection Molding Hyd.vp
P. 14

Konus Burners, Primary, and Vat Pumps

           In the emergency operation, the No. 3WV valve will port all of the oil
           that is supplied by the vat pump back to the Konus burner. The No.
           2WV valve will be closed in the emergency operation. Please refer to
           the “Isolation and Change Out Procedure” for the sequence of
           changing the specific pump.

VSF1 - VSF2 Suction Filters

           These filters will remove contamination from the oil prior to being
           ported to the suction port of the operating vat pump. If the specific
           filter were to become contaminated then cavitation of the pump can
           occur. These filters should be cleaned or changed on a regular basis.

Page 14  Troubleshooting Thermal Oil Systems
   9   10   11   12   13   14   15   16   17   18   19