Konus Burners, Primary, and Vat Pumps

3 Manual Valve

           During normal operation, the valve should be in the closed position.
           When necessary to change the PP2 pump, this valve should be
           opened to allow the fluid to be ported back to the drain tank by the
           drain pump. Please refer to the “Isolation and Change Out
           Procedure” for the sequence that this valve is opened and closed.

4 Manual Valve

           During normal operation, the valve should be in the closed position.
           When necessary to change the PP1 pump, this valve should be
           opened to allow the fluid to be ported back to the drain tank by the
           drain pump. Please refer to the “Isolation and Change Out
           Procedure” for the sequence that this valve is opened and closed.

5 Manual Valve

           When the PP2 primary pump is being used to supply oil to the thermal
           oil circuits, this valve is open. When necessary to bleed the oil out of
           the pump for replacing, the valve should be closed. Please refer to
           the “Isolation and Change Out Procedure” for the sequence for
           opening and closing this valve.

6 Manual Valve

           When the downstream PP2 primary pump is used to supply oil to the
           system, this valve should be in the open position. The valve should
           be closed when necessary to change the pump or filter. Please refer
           to the “Isolation and Change Out Procedure” for the sequence of
           opening and closing this valve.

Troubleshooting Thermal Oil Systems  Page 19