Konus Burners, Primary, and Vat Pumps

PSF1 - PSF2 - PSF3 Suction Filters

           These filters will remove the contamination from the oil prior to being
           directed to the primary pumps. These strainers should be changed
           or cleaned on a regular basis. If the strainer were to become
           contaminated then cavitation of the pump can occur.

PT1 - PT2 Pressure Transducers

           These transducers are used to convert the air pressure in the Konus
           burners into a proportional signal.

VBV Manual Valve

           This 2-inch ball valve is located on the top of the level tank. The valve
           should be open when necessary to vent the volatile gases out of the
           hot oil system. Please refer to the “ Procedure to Vent Volatile Gases
           Off the Hot Oil System” text located in the miscellaneous section of
           this manual for the operation of this valve. VDP Vat Drain Pump

           This pump is located near the log ponds. The pump can be used
           when necessary to drain the oil out of the heat exchanger and
           corresponding line back to the drain tank.

VP1 - VP2 Vat Pumps

           These 1100 GPM, centrifugal type pumps are used to supply thermal
           oil to the HE heat exchanger located in the ponds. Some or all of the
           volume that flows out of the heat exchanger will return back to the
           operating pump’s suction through the No. 2WV directional valve.
           The excess oil will flow through the No. 3WV valve then back into the
           Konus burner.