Page 12 - \\tsclient\C\Users\Jack Weeks\Desktop\TS Injection Molding Hyd.vp
P. 12

Konus Burners, Primary, and Vat Pumps

PP1 - PP2 Primary Pumps

           These 1100 GPM, centrifugal pumps are used to supply oil to all
           circuits and pumps in the thermal oil loop. This includes flow to the
           vat pumps for heating the log ponds, the secondary and counter heat
           pumps on the press, the steam generator, and the various heaters
           located throughout the plant. The No. 1 Konus will supply suction
           fluid to pump No. 1 and Konus No. 2 supplies oil to primary pump No.
           2. Please refer to the “Isolation and Change Out Procedure” for the
           proper sequence of changing these pumps.

PP3 Stand-By Pump

           This 1100 GPM, centrifugal pump is used as a backup for the PP1 or
           PP2 pump. Specific manual valves would have to be opened to allow
           oil from the specific Konus to flow into the pump suction. When
           operating, this pump will supply oil to the vat pump, the press
           secondary and counter heat pumps, the steam generator, and
           various heaters throughout the plant.

Page 12  Troubleshooting Thermal Oil Systems