NO2 Manual Valve

           During normal operation this valve is open. This permits the oil that
           exhausts out of the “AB” port of the No. 3WV valve to flow back into
           the Konus burner. Closing this valve isolates the 3WV valve to the
           Konus burners.

NO3 Manual Valve

           This valve is located near the ponds heat exchanger. During the
           normal mode of operation the valve is open permitting oil flow out of
           the heat exchanger to the No.2WV and 3WV air operated valves.
           The NO3 valve should be closed anytime it is necessary to isolate the
           heat exchanger.

NO4 Manual Valve

           This valve is normally open which allows oil flow from the vat pump
           into the heat exchanger. The valve is located near the heat
           exchanger. Closing the valve isolates flow from the vat pump to the
           heat exchanger.

OV Outlet Valve

           During normal operation, the outlet valve is in the open position. This
           permits oil flow from the VP1 vat pump to be directed to the heat
           exchanger in the ponds. Please refer to the “Isolation and Change
           Out Procedure” for the sequence of opening and closing these valves
           when changing the pump.