Page 20 - \\tsclient\C\Users\Jack Weeks\Desktop\TS Injection Molding Hyd.vp
P. 20

Konus Burners, Primary, and Vat Pumps

18 Manual Valve

           During normal operation this valve is open. In the emergency mode
           of operation the EV1 valve will open allowing flow through valve No.
           18 then to the VP1 suction port. When necessary to isolate or change
           the No. 1 vat pump this valve should be closed. Please refer to the
           “Isolation and Change Out Procedure for the No. 1 Vat Pump” for the
           opening and closing of this valve.

21 Manual Valve

            During normal operation this valve is open. In the emergency mode
           of operation the EV2 valve will open allowing flow through valve No.
           21 then to the VP2 suction port. When necessary to isolate or change
           the No. 2 vat pump this valve should be closed. Please refer to the
           “Isolation and Change Out Procedure for the No. 2 Vat Pump” for the
           opening and closing of this valve.

22 Manual Valve

           This valve is located at the outlet port of the No. 2 vat pump. During
           normal operation this valve is open. Please refer to the “Isolation and
           Change Out Procedure for the No. 2 Vat Pump” in the Miscellaneous
           Section of this manual for the opening and closing of this valve.

23 Manual Valve

           During normal operation, the valve should be in the closed position.
           When necessary to change the VP1 pump, this valve should be
           opened to allow the fluid to be ported back to the drain tank by the
           drain pump. Please refer to the “Isolation and Change Out
           Procedure” for the sequence that this valve is opened and closed.

Page 20  Troubleshooting Thermal Oil Systems