Konus Burners, Primary, and Vat Pumps

CV2 Check Valve

           This check valve will allow the return oil to flow back to the Konus
           burners. When the MV1 manual valve is opened this check valve will
           block the primary pump’s volume to the return line.

EV1 Directional Valve

           This valve is controlled by the AV5 air pilot valve. When in the normal
           mode of operation, the AV5 solenoid is energized, which directs pilot
           pressure to shift the EV1 valve closed. Flow is blocked from the
           operating Konus burner to the suction of the vat pump. In the
           emergency mode of operation, the AV5 solenoid will de-energize. Air
           pressure holding the valve closed will then be ported back to the
           atmosphere. This permits the EV1 valve to shift open. This creates a
           flow path from the No. 1 Konus burner to be ported to the suction line
           of the operating vat pump. The vat pump will then port the oil through
           the HE heat exchanger located in the log pond. The heat exchanger
           will dissipate the heat in the oil to the ponds. The thermal oil will then
           flow through the No. 3WV valve and back into the No. 1 burner.