Konus Burners, Primary, and Vat Pumps

BT Buffer Tank

           As the oil is heated and cooled, it will expand and contract
           respectively by 7% for every 100° of temperature. As the oil expands,
           it will flow into the buffer tank. Some of the heat in the buffer tank will
           be dissipated through the walls and to the atmosphere. This permits
           the oil to cool before flowing into the level tank. The buffer tank is
           located below the level tank. Therefore, the buffer tank will be full of
           oil at all times.

CV1 Check Valve

           This check valve will permit free flow from the primary pumps to the
           inlet of the operating vat pump. When in the normal operating mode,
           the No. 2WV valve will be shifted open allowing some of the oil that
           exhausts out of the ponds heat exchanger, to flow to the vat pump’s
           suction. This check valve will block the oil flow out of valve No. 2WV
           to the No. 3WV valve but allow free flow from the primary pumps to
           the operating vat pump’s suction.

Page 4  Troubleshooting Thermal Oil Systems