Page 16 - Troubleshooting Paper Mill Hydraulics Sample Excerpt 2
P. 16

No. 3 P.M. Winder Power Supply and Rider Roll

24 Pressure Compensating Flow Controls

           These pressure-compensating valves will maintain a constant
           volume of oil through the orifice regardless of the load. The valves are
           connected in a meter in and out type arrangement. The valves control
           the speed that the Rider Roll raises and lowers. If the Rider Roll is
           raising or lowering too slow, then one of the orifices may be plugged
           up. With the hydraulics off, remove the orifice and inspect for
           contamination. Make sure the Rider Roll is fully lowered and
           pressure is at 0 PSI when the No.21 valve is actuated. If the wrong
           type flow control is installed, the cylinders’ speed will vary. When
           replacing the valve make sure the part numbers match exactly.

Page 46  Directional Valves
                      Troubleshooting Papermill Hydraulics
   11   12   13   14   15   16   17   18   19   20